Sign In Join Help
 
Berggruen Technology Co.,Ltd

 
 
Recommended Results 
 
M-Bus Mechanical Heat Metering Apparatus 

  Category : Services->Others->medical instruments

     
M-Bus Mechanical Heat Metering Apparatus
       

  Product Specification
 
  Country  CN
  Brand  Berggruen
  Packing  carton
  Minimum Order  500
  Payment Term  L/C,T/T,Western Union

 

    Product Detail
  <p>
<span style="line-height:1.5;"> </span>
</p>
<p class="MsoNormal" style="text-indent:20.0pt;">
<span style="line-height:1.5;">M-Bus Mechanical Heat Metering Apparatus<br />
</span>
</p>
<p class="MsoNormal" style="text-indent:20.0pt;">
<span style="line-height:1.5;">M-Bus Mechanical Heat Metering apparatus are used for measurement of heat metering in all water based plants with
flow temperatures sensors. The Mechanical heat metering <span>apparatus</span>&nbsp;can realize the long time distance metering with the centralized system with M-Bus function.&nbsp;Our </span><span style="line-height:1.5;">M-Bus Mechanical heat metering&nbsp;<span>apparatus</span>&nbsp;</span><span style="line-height:1.5;"></span><span style="line-height:1.5;">are very easy to
install, read and test but the mechanical heat metering must be installed on the horizontal direction.&nbsp;</span>
</p>
<p class="MsoNormal" align="left">
M-Bus mechanical&nbsp;heat metering <span>Apparatus</span>&nbsp;can calculate the energy for every predetermined water volume. The
energy calculation includes temperature measurement in flow and return as well
as correction for density and heat content according to EN 1434.
</p>
<p class="MsoNormal" align="left">
The specification of <span><span><span>M-Bus Mechanical Heat Metering apparatus</span></span><span></span>&nbsp;</span>is following:
</p>
<p class="MsoNormal" style="text-indent:20.0pt;">
<span style="color:#333333;line-height:1.5;background-color:#FFFFFF;">Diameter DN (MM): &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;DN15&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; DN20&nbsp;&nbsp;&nbsp;&nbsp; DN25 &nbsp; &nbsp;&nbsp;</span>
</p>
<p class="MsoNormal" style="text-indent:20.0pt;">
<span style="color:#333333;line-height:1.5;background-color:#FFFFFF;">qi(m</span><sup>3</sup><span style="color:#333333;line-height:1.5;background-color:#FFFFFF;">/h): &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 0.03 &nbsp; &nbsp; &nbsp;0.05 &nbsp; &nbsp; &nbsp;0.07 &nbsp; &nbsp;</span>
</p>
<p class="MsoNormal" align="left" style="color:#333333;text-indent:9pt;background-color:#FFFFFF;">
qp(m<sup>3</sup>/h) &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 0.6 &nbsp; &nbsp; &nbsp; &nbsp;2.5 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;3.5 &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;
</p>
<p class="MsoNormal" align="left" style="color:#333333;background-color:#FFFFFF;">
&nbsp; qs(m<sup>3</sup>/h) &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 3 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;5 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;7 &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;
</p>
<p class="MsoNormal" align="left" style="color:#333333;background-color:#FFFFFF;">
&nbsp; Function &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; M-BUS, RS485, Pulse, infrared
</p>
<p class="MsoNormal" align="left" style="color:#333333;background-color:#FFFFFF;">
&nbsp;Accuracy class &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 3
</p>
<p class="MsoNormal" align="left" style="color:#333333;background-color:#FFFFFF;">
Pressure loss &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <25kPa
</p>
<p class="MsoNormal" align="left" style="color:#333333;background-color:#FFFFFF;">
Max working pressure &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp; 1.6MPa
</p>
<p class="MsoNormal" align="left" style="color:#333333;background-color:#FFFFFF;">
Temperature range &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4℃&nbsp;~&nbsp;95℃
</p>
<p class="MsoNormal" align="left" style="color:#333333;background-color:#FFFFFF;">
Temperature difference range &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 3℃&nbsp;~&nbsp;70℃
</p>
<p class="MsoNormal" align="left" style="color:#333333;background-color:#FFFFFF;">
<span style="line-height:1.5;">Temperature differential &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;0.01℃</span>
</p>
<p class="MsoNormal" align="left" style="color:#333333;background-color:#FFFFFF;">
Environmental grade &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; A
</p>
<p class="MsoNormal" align="left" style="color:#333333;background-color:#FFFFFF;">
<span style="line-height:1.5;">Battery working time &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;&nbsp;8years</span>
</p>
<p class="MsoNormal" style="color:#333333;background-color:#FFFFFF;">
Installation way &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;horizontal or veritical
</p>
<span style="color:#333333;background-color:#FFFFFF;">Temperature sensor &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;&nbsp;PT1000</span><span style="color:#333333;background-color:#FFFFFF;"></span>
<p class="MsoNormal" style="color:#333333;background-color:#FFFFFF;">
Display digits &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;8digits
</p>
<p>
<img src="http://i.bosscdn.com/product/80/ec/db/5cc8ee44a1ed9a5a3899a5cb40.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=23&p=5&t=80&text=aGVhdG1ldGVyLmJvc3Nnb28uY29t" title="M-Bus Mechanical Heat Metering apparatus" alt="M-Bus Mechanical Heat Metering apparatus" />
</p>meter-technology.com

  More Products from this Supplier
 
Competitive Costs Smart Mechanical Heat Meters with M-bus

Competitive Costs Smart Mechanical Heat Meters with M-bus
Ultrasonic Residential Smart Heat Meters with M-bus

Ultrasonic Residential Smart Heat Meters with M-bus
M-bus Household Mechanical Heat Meters EN1434

M-bus Household Mechanical Heat Meters EN1434
CE Certificated Mechanical Heat Meter with M-BUS

CE Certificated Mechanical Heat Meter with M-BUS
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .