LED Power Supply 5V series S-200W-5 

  Category : Shoes and leather->Shoes->other brands shoes

     
LED Power Supply 5V series S-200W-5
       

  Product Specification
 
  Model No:      S-200W-5
  Country  CN
  Brand  OEM
  Packing  20pcs/ctn
  Minimum Order  100
  Payment Term  L/C,T/T,Money Gram,Western Union

 

    Product Detail
  <p>
LED Power Supply 5V series S-200W-5
</p>
<p>
<br />
</p>
<p>
Common switching power supply is divided into two categories, one is the DC switching power supply, the other is the AC switching power supply.<br />
DC switching power supply is mainly used in the power quality of the poor circuit, it can be less energy quality of the ecological power into a better quality DC voltage, which will help the normal work of various machines. While the AC power switch can only work in the power quality of the better circuit. So in life, the application of DC switching power supply is very wide, and the application of AC switching power supply is relatively small.
</p>
<p>
<br />
</p>
<p>
For this item, followed are the Features:
</p>
<p class="MsoNormal">
1. Universal AC input/Full range
</p>
<p class="MsoNormal">
2. Protection: Short circult/Overload/Over Voltage
</p>
<p class="MsoNormal">
3. Cooling by free air convection
</p>
<p class="MsoNormal">
4. 100% full load burn-in test
</p>
<p class="MsoNormal">
5. No load power consumption &lt; 0.5W
</p>
<p class="MsoNormal">
6. High efficiency, long life and high reliability&nbsp;
</p>
<p class="MsoNormal">
7. One year warranty
</p>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
Details:
</p>
<p class="MsoNormal">
<table class="MsoNormalTable">
<tbody>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Model&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
</p>
</td>
<td width="140" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
S-200-5V
</p>
</td>
<td width="144" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
S-200-12V
</p>
</td>
<td width="131" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
S-200-24V
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
DC Output Voltage
</p>
</td>
<td width="140" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
5V
</p>
</td>
<td width="144" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
12V
</p>
</td>
<td width="131" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
24V
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Iutput Voltage Error
</p>
</td>
<td width="140" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
± 2%
</p>
</td>
<td width="144" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
± 1%
</p>
</td>
<td width="131" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
± 1%
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Rated Output Current
</p>
</td>
<td width="140" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
40A
</p>
</td>
<td width="144" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
16.6A
</p>
</td>
<td width="131" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
8.3A
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Output Current Range
</p>
</td>
<td width="140" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
0-40A
</p>
</td>
<td width="144" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
0-16.6A
</p>
</td>
<td width="131" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
0-8.3A
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Tripple and Noise
</p>
</td>
<td width="140" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
150mVp-p
</p>
</td>
<td width="144" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
250mVp-p
</p>
</td>
<td width="131" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
350mVp-p
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Iniet Stability
</p>
</td>
<td width="140" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
± 0.5%
</p>
</td>
<td width="144" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
± 0.5%
</p>
</td>
<td width="131" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
± 0.5%
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Tolerance Voltage
</p>
</td>
<td width="140" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
± 1%
</p>
</td>
<td width="144" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
± 0.5%
</p>
</td>
<td width="131" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
± 0.5%
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
DC Output Power
</p>
</td>
<td width="140" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
200W
</p>
</td>
<td width="144" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
200W
</p>
</td>
<td width="131" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
200w
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Efficiency
</p>
</td>
<td width="140" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
76%
</p>
</td>
<td width="144" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
78%
</p>
</td>
<td width="131" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
80%
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Adjustable Range for DC Voltage
</p>
</td>
<td width="140" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
4.5-5.6V
</p>
</td>
<td width="144" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
10-13.2V
</p>
</td>
<td width="131" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
20-26.4V
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
AC Input Voltage Range
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
90~132VAC/180~264VAC selected by switch 47~63Hz; 240~370VDC
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Input Current
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
6.5A/115V&nbsp;&nbsp;&nbsp; 4A/230V
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
AC Inrush Current
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Cold-Start Current: 25A/115V, 50A/230V
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Leakage Current
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
&lt;3.5mA/240VAC
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Overload Protection
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
105%~150%&nbsp;&nbsp; Type: Cut Output, Reset: Auto Recovery
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Over Voltage Protection
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Yes
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
High Temperature Protection
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Yes
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Temperature Coefficient
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
± 0.03% /°C (0~50°C)
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Start, Rise, Hold time
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
200ms, 100ms, 20ms
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Vibration
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
10~500Hz, 2G 10min,/1cycle, a total of 60 minutes, Each axes
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Withstand Voltage
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Between Input and Output: 1.5KVAC, Input and Shell: 1.5KVAC, Output and Shell: 0.5KVAC
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Isolation Resistance
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Input and Output Intermal: Input and Enclosule, Output and Enclosure: 500VDC/100M Ohms
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Working Temperature and Humidity
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
`-10°C~+60°C (Refer to Output Dreating Cutive), 20%~90%RH
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Storage Temperature and Humidity
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
`20°C~+85°C, 10%~95%RH
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Overall Dimension
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
210*110*50 mm
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Weight
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
715g
</p>
</td>
</tr>
<tr>
<td width="281" valign="center" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
EMC Standards
</p>
</td>
<td width="417" valign="center" colspan="3" style="border:1pt solid #CCCCCC;">
<p class="MsoNormal">
Meet FCC Part 15J Conduction class B
</p>
</td>
</tr>
</tbody>
</table>
</p>
<p class="MsoNormal">
<img src="http://i.bosscdn.com/product/06/64/3f/f4d2dd7dc047538701062bbaa1.jpg" title="led power supply" alt="led power supply" />
</p>
<p class="MsoNormal">
<img src="http://i.bosscdn.com/product/6b/15/b3/d76d71f5337477801e8911b654.jpg" title="5v led power supply" alt="5v led power supply" />
</p>
<img src="http://i.bosscdn.com/product/3a/10/e9/c1b4a6ebca3142062ebc04d4cf.jpg" width="800" height="1764" title="waweis factory" alt="waweis factory" />
<p>
<br />
</p>
<p>
<br />
</p>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
Please Note:
</p>
<p class="MsoNormal">
1. The testing condition for the parameter above is: 230VAC input, rated load, 25°C 70%Rh, Humidity.
</p>
<p class="MsoNormal">
2. Error, include the setting error, line stability and load stability.
</p>
<p class="MsoNormal">
3. Wave test: adopting "A12" double wire for 20MHZ, and 0.1uF capacitor short-circuit for interrupting.
</p>
<p class="MsoNormal">
4. Inlet Voltage Stability test: when is over load, the lowest voltage of inter is representative to the highest voltage.
</p>
<p class="MsoNormal">
5. Load stability test: the load is from 0% to 100%, others 60%.
</p>
<p class="MsoNormal">
6. C3.4 must be knocked down.&nbsp;
</p>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
Applications:
</p>
<p class="MsoNormal">
•Office , Artwork, Display items lighting;
</p>
<p class="MsoNormal">
•Household lighting;
</p>
<p class="MsoNormal">
•Commercial lighting, such as Flood light, Down light, Flexible strip light, Wall washer, etc;
</p>
<p class="MsoNormal">
•Hotel, Restaurant lighting;
</p>
<p class="MsoNormal">
•Other public facility lighting.
</p>
<p>
<br />
</p>waweis.com

  More Products from this Supplier
 
USB travel charger 5v adapter for mobile phone

USB travel charger 5v adapter for mobile phone
100W 12V 8.3A LED light Use Power Supply

100W 12V 8.3A LED light Use Power Supply
Laptop ac adapter for asus pa-1650-93

Laptop ac adapter for asus pa-1650-93
Notebook Adapter 19V 2.37A for Samsung Galaxy

Notebook Adapter 19V 2.37A for Samsung Galaxy
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .